The Fort Worth Press - France's City of Light switches to climate-resilient power cables

USD -
AED 3.672504
AFN 63.506616
ALL 82.597866
AMD 368.070274
ANG 1.790403
AOA 917.000241
ARS 1461.489297
AUD 1.436441
AWG 1.8
AZN 1.69767
BAM 1.707839
BBD 2.019173
BDT 122.896637
BGN 1.69088
BHD 0.378044
BIF 2989.634336
BMD 1
BND 1.296533
BOB 6.91239
BRL 5.146211
BSD 1.002494
BTN 94.655909
BWP 13.605776
BYN 2.805013
BYR 19600
BZD 2.016285
CAD 1.41783
CDF 2264.999869
CHF 0.809035
CLF 0.023028
CLP 906.31011
CNY 6.774802
CNH 6.784665
COP 3440.13
CRC 454.784115
CUC 1
CUP 26.5
CVE 96.874985
CZK 21.18599
DJF 178.525487
DKK 6.543025
DOP 58.604757
DZD 133.552994
EGP 49.851801
ERN 15
ETB 159.149739
EUR 0.87539
FJD 2.24285
FKP 0.755695
GBP 0.75535
GEL 2.644964
GGP 0.755695
GHS 11.229862
GIP 0.755695
GMD 72.999865
GNF 8784.035073
GTQ 7.628428
GYD 209.275317
HKD 7.839397
HNL 26.670254
HRK 6.596897
HTG 130.960611
HUF 308.869885
IDR 17860.4
ILS 2.989605
IMP 0.755695
INR 94.68375
IQD 1310
IRR 1374999.999751
ISK 126.050277
JEP 0.755695
JMD 158.408737
JOD 0.709031
JPY 161.666989
KES 129.409664
KGS 87.449823
KHR 4012.503045
KMF 430.999908
KPW 900.00035
KRW 1537.614977
KWD 0.3087
KYD 0.835444
KZT 488.630447
LAK 22050.000402
LBP 89550.000067
LKR 335.219143
LRD 182.20319
LSL 16.472163
LTL 2.95274
LVL 0.60489
LYD 6.427478
MAD 9.349975
MDL 17.629557
MGA 4230.000119
MKD 53.954331
MMK 2099.917974
MNT 3579.231668
MOP 8.095209
MRU 40.070206
MUR 47.960333
MVR 15.45996
MWK 1738.365682
MXN 17.407599
MYR 4.139198
MZN 63.89876
NAD 16.472091
NGN 1368.380226
NIO 36.629946
NOK 9.73295
NPR 151.770486
NZD 1.756902
OMR 0.384507
PAB 1.000358
PEN 3.384986
PGK 4.36375
PHP 61.367501
PKR 278.150127
PLN 3.74415
PYG 6111.57296
QAR 3.64598
RON 4.586101
RSD 102.715981
RUB 74.25034
RWF 1464.5
SAR 3.753691
SBD 8.065041
SCR 14.806581
SDG 600.504398
SEK 9.642004
SGD 1.29436
SHP 0.746601
SLE 24.750025
SLL 20969.503664
SOS 572.921224
SRD 37.430495
STD 20697.981008
STN 21.6
SVC 8.771861
SYP 110.532098
SZL 16.410275
THB 33.185503
TJS 9.278635
TMT 3.51
TND 2.911499
TOP 2.40776
TRY 46.479102
TTD 6.798512
TWD 31.666499
TZS 2626.491985
UAH 45.088297
UGX 3651.795772
UYU 40.002096
UZS 11994.999626
VES 616.865275
VND 26317.5
VUV 118.352303
WST 2.751796
XAF 574.021212
XAG 0.016032
XAU 0.000243
XCD 2.70255
XCG 1.80679
XDR 0.713895
XOF 574.016189
XPF 104.850372
YER 238.650145
ZAR 16.447603
ZMK 9001.206935
ZMW 17.769494
ZWL 321.999592
  • RBGPF

    -0.2700

    60.34

    -0.45%

  • CMSD

    -0.2100

    22.08

    -0.95%

  • BTI

    -0.0100

    58.9

    -0.02%

  • GSK

    0.0700

    50.74

    +0.14%

  • NGG

    1.5300

    80.97

    +1.89%

  • BCE

    -0.6300

    22.65

    -2.78%

  • AZN

    1.5000

    176.43

    +0.85%

  • CMSC

    -0.2100

    22.16

    -0.95%

  • BP

    0.6800

    39.78

    +1.71%

  • RIO

    -0.7200

    99.36

    -0.72%

  • RELX

    -0.3500

    30.83

    -1.14%

  • RYCEF

    0.2300

    18.63

    +1.23%

  • JRI

    -0.0200

    12.65

    -0.16%

  • BCC

    -2.1200

    72.54

    -2.92%

  • VOD

    -0.1800

    14.12

    -1.27%

France's City of Light switches to climate-resilient power cables
France's City of Light switches to climate-resilient power cables / Photo: © AFP

France's City of Light switches to climate-resilient power cables

To maintain the glow of the City of Light, Paris is modernising its underground electric cables, vulnerable to damage during heatwaves and dating back 60 years.

Text size:

With power cables melting from Portland to Sicily, the world's 80 million kilometres (50 million miles) of power lines are largely unprepared to resist extreme temperatures, scientists have warned.

The French capital over the next few months will be replacing its obsolete paper-insulated lead-covered cables (PILC), which are made of oil-impregnated paper encased in a lead sheath.

"We're anticipating the renewal of these cables, which are starting to be affected by heat, to have a very resilient network in Paris," said Olivier Lagnel, deputy regional director for utility firm Enedis.

Nearby, workers in orange vests worked in a trench close to the Montparnasse train station to replace the medium voltage PILC, which were installed in 1965, with modern, plastic cables.

State-owned Enedis says Paris is not alone: its counterparts in Chicago, London, Shanghai, Hong Kong, Osaka, Tokyo, Singapore and Sydney also plan to update their cables.

- 'Climate emergency' -

Trouble has mounted in recent years.

Paper-insulated during a 2003 heatwave in France showed weaknesses with "an incident rate multiplied by eight across the medium-voltage underground network", according to a March 2024 report by France's Court of Audit.

Overhead tramway cables melted in Portland in 2021 during record-high temperatures in the northwest US state of Oregon.

A searing heatwave in July 2023 left hundreds of thousands of Sicilians without electricity and water for days.

Heat damage to underground cables was to blame, said supplier e-distribuzione, the distribution arm of energy giant Enel.

"We find ourselves operating in conditions of exceptional climatic emergency," where the temperature of the asphalt on roads reached 50 degrees Celsius (122 degrees Fahrenheit), it said in a statement at the time.

A 2021 study led by Alessandro Bosisio, an assistant professor at the University of Pavia in Italy, found that "an abnormal increase of faults in underground Medium Voltage cable joints has been recorded, especially during summer" worldwide in recent years.

Climate scientists say the period being lived through right now is likely the warmest the earth has seen for the last 100,000 years, back at the start of the last Ice Age.

- Avoid cuts -

PILC cables, which were the international standard from the late 19th century until the 1970s, were long considered highly reliable.

They were wrapped in layers of oily paper intended to isolate the centre of the cable, which heats up as electrons pass through.

The cables were conceived to resist temperatures up to 90C (194F). But when heat is trapped for days under the asphalt, they can reach 120-130C (248-266F) -- ageing faster and eventually risking failure.

Paris's 9,200 kilometres of low- and medium-voltage power cables are entirely buried underground -- to save space and protect them from the wind, Lagnel said.

Enedis plans to phase out the obsolete cables in French cities by 2050.

"The main problem is that the insulator can dry up, and in that case the cable can be sensitive," said Lagnel.

"The idea is to avoid cuts as much as possible" and to "desensitise the network... as heatwaves come back more and more often, stronger and stronger."

N.Patterson--TFWP